Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
The Osseointegration Properties of Titanium Implants with Hydroxyapatite Submicron-Scale Features in the Rabbit Tibia
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 34 , Issue 1
January/February 2014

Pages e18–e25


The Osseointegration Properties of Titanium Implants with Hydroxyapatite Submicron-Scale Features in the Rabbit Tibia


Young-Taeg Sul, DDS, PhD/Ross Towse, BS ChE, MBA


PMID: 24396849
DOI: 10.11607/prd.1685

The objective of this study was to biomechanically and histologically assess the stability and integration of titanium implants that include hydroxyapatite based submicron-scale features. Thirty-four 3.4 mm × 6.5 mm implants, equally split between test (grit blasted, etched, and submicron scale deposition) and control (grit blasted and etched) groups, were placed in the tibiae of New Zealand White rabbits. At 3-weeks follow-up, the group with the submicron deposition showed significantly improved bone response compared with the control group. The test group required higher removal torque values, with its post-torque histology demonstrating both enhanced bone formation and an intact interface indicative of a robust bone-to-implant bond. (Int J Periodontics Restorative Dent 2013;33:e18–e25. doi: 10.11607/prd.1685)


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help